ANALYZER INFORMATION
Storage Temperature -20°C to +50°C
Operating Temperature -5°C to +45°C
Power Supply Rech. batt.: 1500 mAh, mains unit 5V/1A
Memory None
Display Backlit 4-Line
Weight w/ Probe Approx. 700 grams
Dimensions 201 x 83 x 44 mm
Warranty 12 Months
Parameter Measuring range Accuracy Resolution
Temperature
(Flue Gas)
0.0 to 400.0 °C ±1 °C (0,0 to 100,0 °C)
±1.5 % of reading ( > 100 °C)
0.1 °C
Temperature
(Ambient)
-20 to +100.0 °C ± 1 °C 0.1 °C
Draught Measurement -20.00 to +20,00 hPa ± 0.03 hPa (-3.00 to +500 hPa)
± 1.5% of m.v. (remaining range)
0.1 hPa
Pressure Measurement -40,00 to +40.0 hPa ± 0.5 hPa 0.1 hPa
O2 Measurement 0,0 to 21.0 vol.% ± 0.2 vol.% 0.1 vol. %
CO Measurement 0-4000 ppm ±3 ppm (0 to 30 ppm)
±10 % of M.V. (31 to 200 ppm)
±20 ppm (201 - 400 ppm)
±5 % of M.V. (401 to 2000 ppm)
±10 % of M.V. (2001 to 4000 ppm)
1 ppm
Ambient CO
Measurement
0 to 4000 ppm ±3 ppm (0 to 30 ppm)
±10 % of M.V. (31 to 200 ppm)
±20 ppm (201 - 400 ppm)
±5 % of M.V. (401 to 2000 ppm)
±10 % of M.V. (2001 to 4000 ppm)
1 ppm
Determination
(Degree of Effectivity)
0 to 120 % - 0.1 %
Exhaust Gas Loss 0 to 99,9 % - 0.1 %